The exhaust gas generated during the operation of a continuous screw pyrolysis system is not merely the flue gas resulting from the combustion of combustible gases. It also contains trace amounts of uncondensed organic vapors, acidic gases, and particulate matter. Releasing this mixture directly into the atmosphere would not only violate environmental regulations but also negatively impact the surrounding environment. The design of the exhaust gas purification system is therefore critical to ensuring the long-term, compliant operation of the entire pyrolysis plant.


4a144ba95274be930c839d88b24a0748.pngComposition of Pyrolysis Exhaust Gas and Challenges in Purification

The composition of exhaust gas varies significantly depending on the feedstock processed by the screw pyrolysis system. For instance, in the pyrolysis of waste tires, the rubber—which contains sulfur and small amounts of nitrogen—produces sulfur dioxide and nitrogen oxides (NOx) upon the combustion of the non-condensable pyrolysis gases. Furthermore, heavy organic components that escape the condensation system exist as aerosols; these particles are typically too fine to be removed by conventional cyclone separators. Fluctuations in exhaust gas temperature also present challenges: while temperatures at the combustion chamber outlet are high, the gas must be cooled before entering the purification stage. If the cooling process is too rapid, tar components may condense and adhere to the interior of pipes and fan impellers. Given these characteristics, purification strategies cannot simply replicate those used for coal-fired boilers; instead, they must be specifically tailored to the actual composition of the pyrolysis flue gas.

4a144ba95274be930c839d88b24a0748.pngIntegration of Combustion and Rapid Quenching

Ensuring the complete combustion of non-condensable combustible gases within the combustion chamber serves as the primary line of defense against exhaust pollution. This requires the coordinated control of combustion temperature, residence time, and the excess air coefficient. Insufficient temperature or inadequate residence time leads to higher levels of residual carbon monoxide and unburned hydrocarbons, while an excessive supply of air increases the total volume of flue gas and promotes the formation of nitrogen oxides. In auger pyrolysis system, the combustion chamber outlet temperature is typically maintained within a stable range, while an induced-draft fan is used to keep the reaction system at a slight positive pressure. Following combustion, the high-temperature flue gas enters a quenching tower, where it is rapidly cooled to a temperature suitable for subsequent treatment stages. Beyond simply lowering the temperature, this rapid quenching process also inhibits the de novo synthesis of dioxins, which can otherwise occur in lower-temperature zones. Alkali solution is injected into the quench tower, which partially neutralizes acidic gases and reduces the load on downstream scrubbing stages. The atomization performance of the nozzles and the design of the internal flow field within the tower are critical; poor atomization can cause liquid droplets to reach the tower walls before evaporating, leading to "wet walls" and scaling.

4a144ba95274be930c839d88b24a0748.pngFinal-Stage Adsorption and Online Monitoring

Even after quenching and scrubbing, the flue gas may still contain trace amounts of residual organic compounds and fine particulates. A common configuration involves injecting activated carbon—which adsorbs trace organic components and heavy metals—followed by a fabric filter (baghouse) to capture particulate matter. In regions with stricter emission standards, an additional stage, such as an alkali scrubbing tower or a wet electrostatic precipitator, may be incorporated. The exhaust outlet of a continuous screw pyrolysis system is typically equipped with an online monitoring system that continuously records the concentrations of particulate matter, sulfur dioxide, nitrogen oxides, and carbon monoxide. This monitoring data is used not only for environmental regulatory reporting but also as feedback for the control system to adjust combustion and scrubbing parameters. It is important to note that the online monitoring probes themselves require heat tracing and back-purging; otherwise, moisture and tar present in the flue gas can clog the sampling lines, resulting in inaccurate data. The overall reliability of the exhaust gas purification process ultimately depends on whether sufficient safety margins are built into each sub-process, and whether operators promptly adjust reagent dosage and combustion conditions in response to variations in the feedstock.